Join in
Member ID: Password:
Directory and Search for Global Trade

North America

Beliebte Suchen:Hardware-WerkzdegBüroPapier
more
Local Site: Global China Japan Korea Russia Vietnam France Spain India German Italy Argentina

16 Channel Input/Output Board

Hochiki America Corporation

[American]
Contact:
Bo Woods
address:
7051 village drive,suite 100,buena park,ca 
Tel:
1-714-5222246
Fax:
1-714-5222268
Http:
www.hochiki.com 
E-mail:
technicalsupport@hochiki.com

See larger image

Product Type:
Computer Hardware & Software
Post Date :
2014-08-01 10:44:53
Expiry Date:
6 months
Quantity:
1
Specs:
16 Channel Input/Output Board
Payment Method:

  • Product Detail
  • Company Profile
  • Products List
  • Contact
FN-4127-IO STANDARD FEATURES: • 16 channels of input/output points • 32 I/O boards per FireNET panel (512 channels of input/output points) • Each channel configurable as input or output point • Inputs are opto-isolated non-supervised pulldown type triggered by • Outputs are open collector transistor pulldown type (100mA max each) that provide • Simple 4 wire connection to control panel (2 for power, 2 for data) • All inputs/outputs can be assigned to global functions, any event category, and used in network wide Cause & Effect logic • Can be mounted locally within control panel enclosure or remotely via FN-ACC accessory enclosure up to 4000ft from the panel • Each I/O board has a unique address 1-32 (set via DIP switch) on the I/O Comms Bus • Input/Outputs are for secondary use, not for primary fire initiation inputs or notification outputs • Two LED\'s are provided for communication status
Safety For All By our sophisticated life safety, fire detection and emergency devices, people's lives and property are kept protected thus helping make the world a safer place to live. Quality and Value The betterment of society is served by the offering and manufacturing of continually improved products. Community Welfare We strive to improve the lifestyle of each employee, stockholder, business partner and members of the local community whether engaging in work or leisure activities.
FN-4127-IO STANDARD FEATURES: • 16 channels of input/output points • 32 I/O boards per FireNET panel (512 channels of input/output points) • Each channel configurable as input or output point • Inputs are opto-isolated non-supervised pulldown type triggered by • Outputs are open collector transistor pulldown type (100mA max each) that provide • Simple 4 wire connection to control panel (2 for power, 2 for data) • All inputs/outputs can be assigned to global functions, any event category, and used in network wide Cause & Effect logic • Can be mounted locally within control panel enclosure or remotely via FN-ACC accessory enclosure up to 4000ft from the panel • Each I/O board has a unique address 1-32 (set via DIP switch) on the I/O Comms Bus • Input/Outputs are for secondary use, not for primary fire initiation inputs or notification outputs • Two LED\'s are provided for communication status
Bo Woods